Blood Cell Labelling Isolators

Blood cell labelling procedures often involve multiple process stages requiring controlled aseptic preparation to support safe and efficient radiopharmacy workflows. Throughout the process, isolators must maintain product sterility while supporting efficient handling and reliable environmental control. 

Amercare blood cell labelling isolators are designed specifically for these requirements, combining containment, workflow-focused design and integrated process equipment to support efficient blood cell labelling operations while maintaining controlled conditions. 

Whether you require a standard configuration or a system tailored to your specific process, each isolator is engineered to improve dispensing control, reduce handling risks and support consistent efficiency across your workflow. 

✓ Energy Efficient

✓ Market-Leading Quality

✓ ISO 14644-1 Class 5

✓ EU GMP Grade A

Isolators Tailored for Blood Cell Labelling

Amercare blood cell labelling isolators are designed specifically around the workflow demands of blood cell radiolabelling processes, supporting safer handling, reduced transfers and improved process efficiency within a controlled environment. 

A fully integrated centrifuge is incorporated within the base of the isolator and accessed directly from inside the workzone chamber, allowing blood products to remain within the controlled environment throughout processing. This helps reduce transfers, maintain sterility and improve workflow efficiency, while a secure vacuum-seal lid remains locked during operation to ensure safe use. Each system can be fully tailored to your process requirements, with flexible 2 or 4 bucket centrifuge configurations and lead radiation shielding available where required, alongside integrated dose calibrator dippers and real-time activity monitoring to support safe, controlled and efficient blood cell labelling workflows. 

Integrated Centrifuge


Reduces sample transfers and maintains sterility 

Lead Shielding


Radiation exposure protection if required 

Turbulent Airflow


Circulates clean air to dilute contaminants 

Negative Pressure


Protects operators and the lab environment  

Typical Blood Cell Labelling Isolator Features

Amercare Isolators are fully configurable to your requirements through our complementary design service. 

Integrated Centrifuge

  • Integral part of the isolator, fully welded into the base of the unit 
  • Flexible 2 or 4 bucket centrifuge configurations 
  • Controller for control over rotational speed, spin time, acceleration and deceleration rates 
  • Hinged lid with a failsafe lock cannot be opened whilst in-use 
  • 3500 rpm with bucket radius of 160mm generating 2000g maximum 
  • No electrical components or wiring inside the Isolator or centrifuge bowl for safety 
 

Blood Cell Labelling Isolator Features & Options

Market-leading quality   

Fully welded high-grade 3mm 316 stainless steel construction with satin bead blasted and passivated finishes  

 

Included 
Clean air environments   

Equivalent to EU GMP Grade A and ISO 14644-1 Class 5  

 

Included 
High-efficiency filtration   

HEPA filtered inlet and extract air delivers 99.995% efficiency at 0.3 microns (MPPS) 

 

Included 
Gas/odour filtration   

Additional carbon filtration tailored to application 

 

Optional 
Controlled product transfer   

Timed interlock transfer chamber control ensures controlled, sequential door operation and defined dwell times 

 

Included 
Radiation protection   

Lead-lining configurable for up to 360â—¦ protection. Chambers, viewing panels, generator drawer and glove port panels (optional)

 

Optional 
Power loss protection   

Battery backup maintains essential functions including door operation, interlocks and airflow monitoring 

 

Optional 
Superior corrosion resistance   

Constructed from high-grade 316 stainless steel with aluminium and plastic external surfaces 

 

Included 
Accessible cleaning   

Fully accessible external surfaces, with all internal areas accessible through the glove ports 

 

Included 
Contain spillages   

Seamless internal bases with no air grilles, cavities, or inaccessible areas 

 

Included 
Accessible testing   

Accessible test points for routine maintenance and validation protocols

 

Included 
Safe filter change   

Prevent exposure during filter changes with safe change exhaust filters 

 

Included 
Maintain room pressure   

Prevent disruption to surrounding environments during testing with an integrated bypass valve 

 

Optional 
Bio-decontamination   

Gassing connections, gassing doors and a range of hydrogen peroxide vaporisation (HPV) systems available 

 

Optional 
Controlled waste disposal    

Integrated waste bins and chutes with lock functionality 

 

Optional 
Enhanced validation   

Further testing packages available including DQ, FAT, IQ, OQ and gas cycle development (optional)

 

Included
Leak integrity validation   

Integrated automated pressure decay testing with out-of-hours function 

 

Optional
Real-time status   

Microprocessor-based control system monitors and displays isolator status in real-time 

 

Included 
Safe operation assurance   

A digital alarm system monitors key functions and provides immediate visual and audible alerts 

 

Included 
Continuous environmental insight   

Real-time continuous particle monitoring via an integrated isokinetic sampling head inside the chamber 

 

Optional 
Full monitoring capability   

Connections available for gas sterilisation, viable and non-viable air sampling, biological sampling and bespoke requirements 

 

Configurable 
Data traceability   

Automatic data recording and optional printout functionality 

 

Optional 
Facility-wide monitoring and control   

Connect seamlessly with BMS and EMS platforms 

 

Optional 
Save energy costs   

Low-energy EC fans and LED lighting 

 

Included 
Comfortable operation   

Electrical and manual height-adjustable base frames, adjustable footrests and unobstructed knee space 

 

Included / Configurable 
Seamless process integration   

Internal service connections for mains power, data, compressed air, gases, fluid feedline hubs and equipment 

 

Included / Configurable 
Integrated equipment   

Space for or fully integrated process equipment such as centrifuges, sterility testing, automation equipment etc 

 

Centrifuge included 
Simplified product transfer   

Lightweight innovative vacuum seal doors with foot-operated release, wide clear openings, and angled transfer chamber bases 

 

Tailored to isolator 
Organised tools & materials   

Integrated hanging rails, hooks, trays, and shelving 

  

Optional 
Visible processes   

CCTV, display monitors and intercom systems 

 

Optional 
Automated activity measurement   

Integrated dose calibrator dipper measures activity via the ionisation chamber, with foot-operated control for hands-free operation 

 

Optional 
Safe dose preparation   

Integrated lead shielded generator drawers and vial/syringe lifters for protected elution and filling  

 

Optional 

Configuration Options

ExtractTotal loss Thimble 
Recirculating 
Glove port quantity 345
Transfer chambers Standard single 2-glove Manipulating entry 
Glove port size 150mm standard 200mm optional 
Lead shieldingVisor & Body (optional)Glove port panels (optional)
Centrifuge 2-bucket4-bucket 

Standard

Two module Isolator comprising of a Process Isolator with integrated centrifuge and a single Class D transfer chamber. 

Blood Cell Labelling Isolator 3 glove

Manipulating Entry

Two module Isolator comprising of a Process Isolator with integrated centrifuge and a 2-Glove manipulating Class D transfer chamber. 

Blood Cell Labelling Isolator 5 glove

Standard Configuration Dimensions

Configuration Length (mm) Depth (mm) Max Height (mm) 
Standard transfer chamber – 3 ports 1670 740 1990 (+ 150mm for recirculating extract) 
Standard transfer chamber – 4 ports 2270 740 1990 (+ 150mm for recirculating extract) 
Manipulating entry chamber – 3+2 ports 2160 740 1990 (+ 150mm for recirculating extract) 
Manipulating entry chamber – 4+2 ports 2560 740 1990 (+ 150mm for recirculating extract) 

Supporting You and Your Isolator
for Life

Amercare supports the ongoing performance, reliability and safe operation of all isolators with a range of in-stock consumables, replacement components, planned servicing , and available technical support. This ensures consistent operation, reduced downtime, and long-term support throughout the lifecycle of your system.

Contact our team

Tailor your isolator to your specific requirements with our complimentary design service.

Arrange your free consultation and no-obligation quote today.