bioquell amercare gassing isolator

Amercare x Bioquell (Ecolab) Gassing Isolator

Amercare can supply isolators with the Bioquell (Ecolab) Port II and L-4 VHP generators.  

The L-4 generator provides a reliable and robust solution for vapourised hydrogen peroxide (VHP) generation, while the Port II offers higher capacity with rapid cycle capability, achieving batch decontamination in as little as 25 minutes. 

This configuration also enables multiple isolators to be connected for coordinated, multi-step gassing processes, supporting higher throughput and more complex operational workflows. 

✓ Batch decontamination in as little as 20 minutes

✓ Ability to connect multiple isolators for multi-step processes

✓ Supports high-throughput workflows

Amercare Isolators are fully configurable to your requirements through our complementary design service. 

gassing isolator
gassing isolator
Gassing isolator integrated waste chutes
Controlled disposal with lockable waste chutes and rigid pods or heat sealable bagging out systems available.
gassing isolator visor open
Hinged front panel allows large items of equipment to be moved in and out of the process section.
gassing isolator racking
Racking and trolley options for efficient presentation of loads to hydrogen peroxide vapour.

Amercare Isolator Features

Market-leading quality   

Fully welded high-grade 3mm 316 stainless steel construction with satin bead blasted and passivated finishes  

 

Included  
Clean air environments   

Equivalent to EU GMP Grade A and ISO 14644-1 Class 5  

 

Included  
High-efficiency filtration   

HEPA filtered inlet and extract air delivers 99.995% efficiency at 0.3 microns (MPPS) 

 

Included  
Gas/odour filtration   

Additional carbon filtration tailored to application 

 

Optional 
Controlled product transfer   

Timed interlock transfer chamber control ensures controlled, sequential door operation and defined dwell times 

 

Included  
Power loss protection   

Battery backup maintains essential functions including door operation, interlocks and airflow monitoring

 

Included 
Superior corrosion resistance   

Constructed from high-grade 316 stainless steel with aluminium and plastic external surfaces 

 

Included 
Accessible cleaning   

Fully accessible external surfaces, with all internal areas accessible through the glove ports 

 

Included  
Contain spillages   

Seamless internal bases with no air grilles, cavities, or inaccessible areas 

 

Included  
Accessible testing   

Accessible test points for routine maintenance and validation protocols 

 

Included 
Safe filter change   

Prevent exposure during filter changes with safe change exhaust filters 

 

Included 
Maintain room pressure   

Prevent disruption to surrounding environments during testing with an integrated bypass valve 

 

Optional 
Bio-decontamination   

Gassing connections, gassing doors and a range of hydrogen peroxide vaporisation (HPV) systems available 

 

Included 
Controlled waste disposal    

Integrated waste bins and chutes with lock functionality

 

Optional 
Enhanced validation   

Further testing packages available including DQ, FAT, IQ, OQ and gas cycle development (optional)

 

Included 
Leak integrity validation   

Integrated automated pressure decay testing with out-of-hours function 

 

Included  
Real-time status   

Microprocessor-based control system monitors and displays isolator status in real-time 

 

Included  
Safe operation assurance   

A digital alarm system monitors key functions and provides immediate visual and audible alerts 

 

Included  
Continuous environmental insight   

Real-time continuous particle monitoring via an integrated isokinetic sampling head inside the chamber 

 

Optional 
Full monitoring capability   

Connections available for gas sterilisation, viable and non-viable air sampling, biological sampling and bespoke requirements 

 

Configurable 
Data traceability   

Automatic data recording and optional printout functionality 

 

Optional 
Facility-wide monitoring and control   

Connect seamlessly with BMS and EMS platforms 

 

Optional 
Save energy costs   

Low-energy EC fans and LED lighting 

 

Included 
Comfortable operation   

Height-adjustable base frames, adjustable footrests and unobstructed knee space 

 

Configurable 
Seamless process integration   

Internal service connections for mains power, data, compressed air, gases, fluid feedline hubs etc 

 

Configurable 
Integrated equipment   

Space for or fully integrated process equipment  

 

Optional 
Simplified product transfer   

Lightweight innovative vacuum seal doors with foot-operated release, wide clear openings, and angled transfer chamber bases 

 

Tailored to isolator 
Organised tools & materials   

Integrated hanging rails, hooks, trays, and shelving 

 

Optional 
Visible processes   

CCTV, display monitors and intercom systems 

 

Optional 

Standard Configuration Options

Glove ports34
Chamber pressure Negative Positive 
Transfer chamber Standard Rapid transfer 
Entry chamber Standard Gloved 
Extract Total loss / thimbleRecirculating 
Gas generator Fully integrated Freestanding connections 

Technical Information

Transfer Chamber Air Quality Type D or E, High Flow Turbulent ECGMP Grade A 
Carcass Materials Grade 316L Stainless Steel 
Main Chamber Pressure (+ve) +100Pa (+ve) or -250Pa (-ve) 
Transfer Chamber Pressure (+ve) +70Pa (+ve) or -300Pa (-ve) 
Leak Classification ISO 14644 Class 3 
Main Chamber Inlet Filter HEPA Grade H14 
Main Chamber Extract Filter HEPA Grade H14 
Transfer Chamber Inlet Filter HEPA Grade H14 
Transfer Chamber Extract Filter HEPA Grade H14 
Secondary Extract Filter HEPA Grade H14 
Air Extract Rate 0.08m3/s for main chamber plus 0.04m3/s for each transfer chamber.  
Lighting Low Energy lighting to provide glare free minimum 750lux at the working position. 
Sound level Less than 65DbA at the working position. 
Power supply Either 240v or 110v AC 
Service requirements Electrical supply & ducted extract with remote fan. 

Supporting You and Your Isolator
for Life

Amercare supports the ongoing performance, reliability and safe operation of all isolators with a range of in-stock consumables, replacement components, planned servicing, and available technical support. This ensures consistent operation, reduced downtime, and long-term support throughout the lifecycle of your system.

Contact our team

Tailor your isolator to your specific requirements with our complimentary design service.

Arrange your free consultation and no-obligation quote today.